| 90NET | 80NET |
![]() | ![]() |
| 70NET | Excor Apodys(工業(yè)級UPS,法國原裝進口設(shè)備) |
一、90NET 系列UPS介紹
90NET系列UPS采用用基于微處理器控制的 IGBT 逆變器,通過矢量控制技術(shù)可以顯著提高逆變器性能。為提高系統(tǒng)冗余可靠性,UPS 內(nèi)置了獨立的靜態(tài)旁路開關(guān)。此外,通過加裝一些系統(tǒng)組件,如并聯(lián)套件、并機輸出柜、CROSS 靜態(tài)開關(guān)、安全切斷裝置、系統(tǒng)維護旁路以及軟件和通訊套件等,更能為負載提供至高等級的全面電源保護。(詳細資料請致電021-34553681)
| 型號 | 功率(kVA) | 型號 | 功率(KVA) |
| 90-NET/60 | 60 | 90-NET/250 | 250 |
| 90-NET/80 | 80 | 90-NET/300 | 300 |
| 90-NET/100 | 100 | 90-NET/400 | 400 |
| 90-NET/120 | 120 | 90-NET/500 | 500 |
| 90-NET/160 | 160 | 90-NET/600 | 600 |
| 90-NET/200 | 200 | 90-NET/800 | 800 |
二、80NET 系列UPS介紹
80-NET系列UPS電源采用雙 DSP 和微型控制器,提供了 UPS 行業(yè)最強大的控制能力;而向量控制技術(shù)則增強了這些轉(zhuǎn)換器的性能。為了增加系統(tǒng)冗余,該 UPS 集成了一個獨立的電子靜態(tài)旁路。通過增加系統(tǒng)組件、CROSS 開關(guān)、安全和分斷裝置、系統(tǒng)旁路開關(guān)以及軟件和通訊解決方案,可以構(gòu)建精密的系統(tǒng)確保對負載提供完全保護。(詳細資料請致電021-34553681)
系統(tǒng)特點:
電能質(zhì)量更高
完全輸入功率因數(shù)校正(PFC),并且 THDi 非常低
完全兼容任何 TN 和 IT 安裝
完全兼容任何備用發(fā)電機
完全兼容任何性質(zhì)的、PF 高達 1 的負載而不需要降額
電力中斷保護
高級電池保養(yǎng)
高效節(jié)能
無變壓器的設(shè)計(可提供電流隔離變壓器作為集成式獨立選件)這種 UPS會在商用 AC 電源斷電或降級的情況下自動在規(guī)定的限度內(nèi)不間斷地繼續(xù)供電。發(fā)生網(wǎng)絡(luò)故障時的連續(xù)使用時間(即后備供電時間)取決于電池容量。
| 型號 | 功率(kVA) | 型號 | 功率(KVA) |
| 80-NET/60 | 60 | 80-NET/200 | 200 |
| 80-NET/80 | 80 | 80-NET/300 | 300 |
| 80-NET/100 | 100 | 80-NET/400 | 400 |
| 80-NET/120 | 120 | 80-NET/500 | 500 |
| 80-NET/160 | 160 |
三、70NET 系列UPS介紹
CHLORIDE是一家由英國標準協(xié)會 (BSI)認證,具有ISO9001 和ISO14001 保證體系標準的公司。
70-NET具有歐共體CE標志認證,符合安全和EMC電磁兼容標準73/23, 93/68,和89/336,92/31,93/68。 70-NET是按照以下國際標準設(shè)計生產(chǎn)的:
IEC/EN 62040-1-1 (通用安全規(guī)范)
EN50091-2 (電磁兼容規(guī)范)
IEC/EN 62040-3 (操作規(guī)范標準)
UPS包括以下主要功能模塊
交流/直流轉(zhuǎn)換器:整流器將市電交流轉(zhuǎn)換成直流,通過直流總線向逆變器供電,整流器從市電中只吸收有功功率(功率因數(shù)校正功能)。
電池充電器:提供紋波電壓和電流都極低的直流對電池進行充電,以便將電池組完全充滿。
升壓器:直流/直流轉(zhuǎn)換器會提升整流器/電池輸出的直流電壓,建立分離直流總線,用于逆變器產(chǎn)生交流電壓而不需要輸出變壓器。
直流 / 交流轉(zhuǎn)換器。無變壓器的I G B T 逆變器由數(shù)字信號處理器(DSP)控制。
帶單獨輸入的靜態(tài)旁路:旁路備用電源上的靜態(tài)開關(guān)采用先通后斷技術(shù)。通過手動或自動指令可將負載從逆變器切換到旁路,反之亦然。
手動維護旁路開關(guān):此手動開關(guān)可以在無需中斷負載電源的情況下對UPS內(nèi)部進行維護。
UPS內(nèi)置電池:10-40 kVA UPS可內(nèi)置電池,以獲得短時間的后備延時。
配套電池柜:用于長延時電池配置。
| 型號 | 功率(kVA) | 型號 | 功率(KVA) |
| 70-NET/10 | 10 | 70-NET/40 | 40 |
| 70-NET/15 | 15 | 70-NET/50 | 50 |
| 70-NET/20 | 20 | 70-NET/60 | 60 |
| 70-NET/30 | 30 |
四、Excor Apodys 工業(yè)級UPS介紹(英文)
Excor Apodys - AC UPS system from 2.5 kVA to 500 kVA
The Excor Apodys range of industrial Uninterruptible Power Systems (UPS) is available from 2.5 to 120 kVA as standard, in single or three-phase output configurations and may be customized to reach up to 500 kVA.
Flexibility for customised solutions
Excor Apodys is fully adaptable to changes in electrical load: power upgrades are quickly and successfully achieved by connecting up to 8 units in parallel.
Higher ratings can be designed for specific power protection requirements (up to 200 kVA 1ph, and 500 kVA 3 ph).
If the only mains voltage available on the installation site is single phase, both Apodys Excel and Exond ranges can be combined to provide a double conversion specific UPS with single-phase input.
A full range of additional options is available to offer tailored industrial solutions:
AC and/or DC distributions
Isolated DC/DC converters
Up to IP54 external protection
Modular or centralised parallel configurations
EEx battery protection boxes.
Leading technology
Chloride employ patented Vector Control technology to increase the performance of power components and enable active conditioning of the load. The result is improved reliability for processes and enhanced safety for personnel, even in the harshest operating environments.
The innovative modular assembly allows us to satisfy the most demanding international project schedules.

The product design affords easy front-access to all vital modules of the system. As a result, maintenance times are significantly reduced.
Reliability
Excor Apodys provides lasting secure power architecture for your industrial applications thanks to:
On-line double conversion topology
Continuous operation at full load in a permanent 40°C ambient temperature
System lifetime of at least 20 years in continuous operation conditions
Robust mechanical design (vertical and horizontal acceleration stress up to 0,5g).
Communication
Excor Apodys uses intuitive multilingual digital graphic control, meaning system status, measurements and alarms are accessible from the front panel of the UPS. The embedded ‘Event Log’ function allows the user to trace the last 100 events. Event memory is activated from the first event appearance on.
RS232, RS485 and voltage-free contacts allow the monitoring of UPS on SCADA systems.
Advanced battery care
Excor Apodys is fully compatible with lead-acid and nickel-cadmium batteries, sealed or vented. A programmable battery test evaluates the efficiency of your battery.
Tests on individual cells are achieved by employing our latest battery management system.
Battery cabinets matching the UPS system cabinet can be offered, regardless of the autonomy needed.
Monitoring
The Apodys family is fully compatible with LIFE.net, Chloride’s remote monitoring service, which provides:
Continuous real time UPS monitoring
Regular transmission of an operating status report
UPS performance analysis
Power quality monitoring to analyse mains disturbance trends.
Applications
Excor Apodys protects heavy duty applications, such as:
Oil and gas offshore and onshore
Refining, petrochemicals
Power generation plants
Transportation (rail, metros…).
Secure Power Always
In order to reach the highest level of business continuity, Chloride offers a range of maintenance plans, which will:
Help deliver reliability to your load
Increase the lifetime of your power protection equipment
Optimise your capital expenditure
Provide risk management at a fixed cost
Provide a pro-active approach to disaster recovery.
For more information please contact your local Chloride sales office.
Delegate your power management to the experts.
RANGE OF RATINGS (kVA) | 2.5 | 5 | 7.5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 80 | 100 | 120 (up to 500 kVA available on request) | |||||
Output type | One-phase output | Three-phase output | |||||||||||||||||
Intermediate DC voltage (VDC) | 110 | 110 | 220 | 220 | 400 | 400 | 110 | 110 | 220 | 220 | 400 | 400 | |||||||
Output AC voltage (VAC) | 1 x 110 | 1 x 230 | 1 x 110 | 1 x 230 | 1 x 110 | 1 x 230 | 3 x 220 | 3 x 400 | 3 x 220 | 3 x 400 | 3 x 220 | 3 x 400 | |||||||
Available range of ratings (kVA) | 2.5 - 60 | 2.5 - 60 | 10 - 100 | 10 - 120 | 40 - 120 | 40 - 120 | 5 - 50 | 5 - 50 | 15 - 100 | 15 - 100 | 40 - 120 | 40 - 120 | |||||||
TECHNICAL CHARACTERISTICS | ||
INPUT | ||
Nominal AC voltage (VAC) | 3 x 400 (3 x 380,3 x 415) | |
Tolerance (%) | +15/-10 | |
Nominal frequency (Hz) | 50 (60) | |
Tolerance (%) | ± 5 | |
INTERMEDIAIRE DC CIRCUIT | ||
DC voltage (VDC) | 110 / 220 / 400 | |
Rectifier output voltage stability | < 1 % | |
Rectifier output voltage ripple | < 2 % RMS in floating mode | |
Inverter input voltage range | -20% / +18% | |
OUTPUT | ||
Nominal AC output voltage (VAC) | 1x110(120) ; 1x230 (220,240) | 3 x 220; 3 x 400 (380,415) |
Frequency (Hz) | 50 (60) | |
Available ratings (kVA) | see above | |
Frequency response | < 1 Hz / sec | |
Frequency stability with own oscillator with mains synchronisation | ± 0,05% ± 3% (from 0,2 to 6% adjustable) | |
Harmonic distorsion | < 3% | |
with 100% linear load | ||
with 100% non-linear load - CF 3/1 | < 5% | |
Synchronisation voltage limits | ± 15% | |
Output voltage stability | ±1% | |
(for 0-100% load variation) | ||
static (balanced load) | ||
static (unbalanced load) | ±2% | |
dynamic | ±3% | |
Overload capacity | 125% for 10min. / 150% for 60 sec. | |
Short-circuit capability | 250% (100ms) - 175% (5s) | 315% (100ms) - 240% (5s) - Ph/N |
Load power factor | 0,5 lagging to 0,9 leading | |
Output Crest factor admissible | 3:1 | |
GENERAL DATA | ||
Operating temperature (°C) | 0 - 40 (in permanent operation conditions) | |
Relative humidity (%) | < 95% (non condensing) | |
Storage temperature (°C) | -20 to +70 | |
Operating altitude (m) | 1000 (without derating) | |
Cooling | Fan assisted | |
External protection | IP 20* | |
Internal protection | IP 20 | |
Lock | Steel locked door with door handle | |
Frame colour | Grey RAL 7032 textured semi-gloss | |
Dimensions | Varying according to ratings and options | |
STANDARDS | ||
Compliance | IEC 950, 439, 146, 529, 726, EMC (62040-2) and safety (62040-1-2) | |
US Standards | Manufacturing following UL, ANSI, NEMA, IEEE standards is available upon demand | |
OPTIONS | ||
Rectifier | 12-pulse rectifier, harmonic filters, ripple filters | |
Battery | Battery protection box, low-voltage disconnect contactor, battery management system, matching battery cabinet | |
Reserve | By-pass transformer, by-pass stabiliser, by-pass harmonic filters | |
System | Parallel configurations, DC/DC serial regulator, isolated DC/DC converter, distribution, meters, volt-free contacts, serial link, PPVis monitoring software | |
Mechanical | Up to IP54 external, top cable entry, other frame colour, anti-seismic design | |